CTA Three-Stage Filter Cartridge Replacement Guide: Maximize Compressed Air Purity & Save Cost

Why CTA Three-Stage Filtration Matters

In industrial compressed air systems, clean, dry, and oil-free air is critical for protecting downstream equipment and ensuring product quality. The CTA (Coalescing + Treatment + Adsorption) three-stage filter system is the industry standard for removing contaminants, with the A-grade activated carbon filter as the final stage that eliminates vapors and odors.

A frequent question from global clients is:
👉 Should the third-stage filter cartridge be replaced every 4000 hours or 8000 hours?
This guide helps you optimize maintenance, reduce cost, and ensure uncompromising compressed air purity.


4000 Hours vs 8000 Hours: What’s the Right Interval?

  • 4000 hours (≈1 year): A conservative, safety-first guideline. Guarantees air purity for sensitive industries like food & beverage, pharmaceuticals, and electronics.

  • 8000 hours (≈2 years): Possible only under ideal conditions: clean intake air, effective pre-filters, low oil vapor content, and stable operating temperatures.

📌 Key Point: Don’t rely only on time. The real filter life depends on your operating environment.


How the CTA Three-Stage Filter System Works

  1. Coalescing Filter (C-Stage): Removes bulk water and oil aerosols.

  2. Particulate Filter (T-Stage): Captures solid particles down to micron size.

  3. Activated Carbon Filter (A-Stage): Adsorbs residual oil vapors and odors.

    • Once saturated, the A-stage filter cannot trap oil vapors—risking product contamination and equipment damage.


3 Methods to Determine Optimal Filter Replacement

1. Monitor Differential Pressure (ΔP)

  • All housings include a ΔP gauge.

  • As filters load with contaminants, ΔP rises.

  • 액션: Replace when ΔP reaches 0.7–1.0 bar to prevent energy waste and failure.

2. Test Downstream Air Quality

  • Use oil vapor test kits or analyzers.

  • 액션: Replace immediately if oil vapor approaches ISO 8573-1 limits (Class 0 or Class 1).

3. Track with Maintenance Logs

  • Record hours, conditions, and ΔP at each inspection.

  • 결과: Build a customized, cost-effective replacement cycle for your facility.


Best Practice Recommendations

  • 사용 4000 hours as a safe baseline.

  • Let the differential pressure gauge be your main replacement guide.

  • Validate with air quality tests for ISO 8573-1 compliance.


Why Choose Us as Your Filtration Partner?

  • Expert Guidance: Technical advice tailored to your application.

  • Premium CTA Filter Cartridges: Long service life, reliable ISO 8573-1 purity, low energy consumption.

  • Cost-Effective Procurement: Standard and custom solutions with competitive pricing.


Call to Action

Ready to maximize compressed air purity while saving costs?
👉 [Contact Us Today for a Free Consultation & Quotation] – Let our experts provide the right CTA three-stage filter cartridge solution for your system.

John  사진

John

다이어프램 컴프레서 선택 및 유지보수에 관한 Keepwin의 기사를 읽은 후 수소 및 산소와 같은 고순도 가스를 압축하는 데 중요한 요소를 명확하고 체계적으로 이해할 수 있게 되었습니다. 이 게시물은 탄탄한 데이터와 API 618 레퍼런스를 이란의 실제 90bar 프로젝트 사례와 결합하여 Keepwin의 맞춤화 역량과 제공 강점을 설득력 있게 보여줍니다. 특히 ROI 계산과 유지보수 비용 비교를 포함함으로써 엔지니어가 장비를 선택할 때 직면하는 어려움을 직접적으로 해결해 주는 사용자 중심의 콘텐츠였습니다. 앞으로도 이런 콘텐츠가 더 많이 나오기를 기대합니다!

답글 남기기

이 사이트는 Akismet을 사용하여 스팸을 줄입니다. 댓글 데이터가 어떻게 처리되는지 알아보세요.

ko_KR한국어

압축기 솔루션 받기

전문 엔지니어가 고객의 요구에 맞는 솔루션을 설계할 수 있도록 준비해 드립니다.

*저희는 사용자의 개인정보를 존중합니다. 제출하시면 Keepwin의 전담 전문가가 최대한 빠른 시일 내에 연락을 드릴 것입니다.